Galvanized steel deck is suitable for steel structure construction to improve its stiffness. It is made of high-zinc galvanized sheets and profiled through rolling and cold bending, which offer excellent corrosion resistance and great durability. Corrugated metal deck is used for supporting floor concrete, including structural roof deck or composite floor deck.
A floor deck is a kind of corrugated metal panel for floor application. It is also called composite deck because it is a combination of concrete and metal roof panels. The floor deck serves as the tensile reinforcement to improve the rigidity of the floor panel and reduce the usage of reinforcement and concrete.
(1)Light weight, high strength, good bearing performance, good anti-seismic performance;
YX51-250-750Construction Maximum Unsupported Span | ||||
Floor thickness (mm) |
Steel plate thickness (mm) ) |
Maximum unsupported span (=) | ||
I-span | 2-spans | 3-spane | ||
100 | 0.8 | 2.15 | 2.5 | 2.6 |
1 | 2.7 | 2.9 | 3 | |
1.2 | 3 | 3.32 | 3.45 | |
1.4 | 3.38 | 3.67 | 3.89 | |
1.6 | 3.52 | 3.91 | 4.14 | |
125 | 0.8 | 1.98 | 2.3 | 2.4 |
1 | 2.35 | 2.7 | 2.85 | |
1.2 | 2.68 | 3 | 3.2 | |
1.4 | 3.07 | 3.36 | 3.45 | |
1.6 | 3.26 | 3.59 | 3.72 | |
140 | 0.8 | 1.88 | 2.2 | 2.27 |
1 | 2.25 | 2.56 | 2.65 | |
1.2 | 2.5 | 2.79 | 2.95 | |
1.4 | 2.87 | 3.16 | 3.32 | |
1.6 | 3.05 | 3.38 | 3.56 | |
150 | 0.8 | 1.8 | 2.15 | 2.23 |
2.2 | 2.45 | 2.58 | ||
1.2 | 2.45 | 2.65 | 2.85 | |
1.4 | 2.69 | 2.82 | 3.18 | |
1.6 | 2.9 | 3.18 | 3.34 | |
165 | 0.8 | 1.75 | 2.06 | 2.13 |
1 | 2.1 | 2.39 | 2.44 | |
1.2 | 2.34 | 2.58 | 2.78 | |
1.4 | 2.57 | 2.75 | 3.03 | |
1.6 | 2.78 | 2.94 | 3.17 | |
185 | 0.8 | 1.66 | 1.96 | 2.03 |
1 | 1.95 | 2.3 | 2.35 | |
1.2 | 2.21 | 2.5 | 2.63 | |
1.4 | 2.4 | 2.66 | 2.85 | |
1.6 | 2.56 | 2.8 | 3.03 | |
"3. The maximum permissible vertical disturbance is 1/180 of the clear span or 20mm both whichever is the minimum. Unsupported span change. 4, stress calculation in accordance with the specification, uniform load 1.5KN / M2, concentrated load 2.2KN / U2." |